GB Conventional Round Flame Burner

GB Conventional Round Flame Burner GraphicBurner Description:

The Zeeco GB Conventional round flame gas only burner.

Burner Design Features:

GB Conventional Round Flame Burner Graphic

Burner Design Information

Burner Model: GB Conventional Burner
Fuels: Gas Only
Description: Round Flame Conventional Emissions Burner
NOx Reduction Method: None
Predicted NOx Emissions Range (Natural Draft): 90 ppmv to 200 ppmv
Predicted NOx Emissions Range (600F Air Preheat): 150 ppmv to 400 ppmv
Combustion Air Induction: Natural, Forced, Induced & Balanced Draft
Mounting Options: Up-fired and Side-fired
Natural Draft Heat Release Range: 1 MM to 20 MM Btu/hr [0.293 to 5.860 MW]
Forced Draft Heat Release Range: 1 MM to 50 MM Btu/hr [0.293 to 14.650 MW]
Turndown: 10:1
Typical Excess Air Range: 10% to 25%