ZEECO RESOURCES | Brochures

GLSF Min-Emissions Round Flame Gas Burner

Written by Zeeco | May 24, 2021 12:18:08 AM

The ZEECO® GLSF Min-Emissions Burner is an ultra-low emissions round flame burner. Our design allows for a compact flame shape, making it a great choice for retrofit applications that require burners closely mounted together or far apart while still achieving ultra-low NOx emissions levels.

 Minimum Emissions Round Flame Gas Burners

Individual Minimum Emissions Round Flame Gas Burner

 

Why Choose Zeeco?

Zeeco leads today’s global market in the design of combustion equipment. Our engineers have the experience, knowledge, and tools to properly design your burner equipment. Zeeco’s burners have been operating around the globe for more than 40 years. Our philosophy is to provide customers with superior quality, on-time shipments and competitive pricing, which is the cornerstone of our success. Let us put our experience to work for you. Call or email us today to learn more about the full line of ZEECO® burner products and replacement components for your new or existing burner system.

 

Design Features

  • Stable flame over a wide range of conditions
  • High turndown of 5:1 or greater for most cases
  • No stabilization metal used in the burner throat
  • Low maintenance cost since tip mass is small and exposed into firebox less than 1” (25 mm)
  • Compact design makes this burner a great choice for retrofit applications
  • Compact flame shape
  • Great heat flux profile
  • Reasonable cost and great value
  • Combustion air dampers are controlled by gears for precise control
  • Bearings are used for the combustion air dampers for smooth, precise operation
  • Plenum mounted or individual wind-box configurations
  • 310 stainless steel (type HK) gas tips

 

Design Information

Burner ModelGLSF Min-Emissions Burner
FuelsGas Only
DescriptionRound Flame Ultra-Low Emissions
NOx Reduction MethodInternal Flue Gas Recirculation by FREE-JET Mixing
Predicted NOx Emissions Range (Natural Draft)30 to 45 ppmv
Predicted NOx Emissions Range (600˚ F (316˚ C)Air Preheat)50 to 80 ppmv
Combustion Air InductionNatural, Forced, Induced, & Balanced Draft
Mounting OptionsUp-fired and Side-fired
Natural Draft Heat Release Range1 to 20 MMBtu/hr [0.293 to 5.860 MW]
Forced Draft Heat Release Range1 to 50 MMBtu/hr [0.293 to 14.650 MW]
Turndown5:1
Typical Excess Air Range10 to 25%